CURRENT LOCATION:HOME >> PRODUCT >>  Flaw Detector Series >>  Ultrasonic Flaw Detector
thumb
thumb
thumb

JITAI9101 Ultrasonic Flaw Detector

Measuring Range (mm):0 ~10000mm
Channels:500
Frequency Range (MHz):0.2 ~20MHz
Material Velocity (m/s): 1000 ~15000m/s
Vertical Linearity Error: ≤3%
Horizontal Linearity Error: ≤0.1%
Dynamic range: ≥32dB
  • detailed
  • Technical index



Features:

*Automated calibrationAutomated gain

*DACAVGTCGB scanAWS

*High-speed capture and very low noise

*High contrast viewing of the waveform from bright

*Powerful pc software and reports can be export to excel

Functions:

*Automated display precise flaw location(Depth dlevel pdistance samplitudesz dBф);

*Automated switch three staff gauge ((Depth dlevel  pdistance s);

*Automated calibration of transducer Zero-point, Angles, Front edge and material Velocity;

*Convenient to make and use DACTCG and AVG to evaluate the echo, the curve can be modified and compensated

*6dB DAC functions;

*500 independence setup, any criterion can be input freely, we can work in the scene without test block;

*Big memory of 500 A graph;

*Automated gain and gain scan;

*Peak Hold and Peak Memory;

*B scan;

*AWS D1.1

*Automated make video of test process and play; use upan,the length of video is unlimited.

*Powerful pc software and reports can be export to excel;

*Li battery, continue working time up to 12 hours;

*The embeded software can be online updated


Other assistant function:

*Display freeze;

*Automated echo degree;

*Angles and K-value;  

*Lock and unlock function of system parameters;

*Electronic clock calendar ;  

*Two gates setting and alarm indication;

*Gate and DAC alarm;


Specifications:

*Measuring Range (mm):0 ~10000mm

*Channels: 500

*Frequency Range (MHz)0.2~20MHz

*Material Velocity (m/s): 1000 ~15000m/s

*Vertical Linearity Error: ≤3%

*Horizontal Linearity Error: ≤0.1%

*Sensitivity Leavings: ≥62dB

*Dynamic range: ≥32dB

*Resolving Power: ≥36dB

*Gain (dB): 0 ~120dB

*Measurement Mode: SingleDualThru

*Reject: 0~80%

*Pulse Displacement (μs): -20 ~+3400

*Zero (μs): 0.0 ~99.99

*Port Type: BNC(Q9) or Lemo 01(C9)

*Operating Temperature (℃): -20~70

*H*W*D(mm): 240*156*48

*Weight (kg):1.0with battery


Standard Configration:

*Main Body                              1

*Straight Beam Probe              1

*Angle Probe                           1

*Machine-probe Cable             1

*Power Adapter (Charger)        1

*Data proceeding Software      1

*USB communication Cable      1

*Manual                                    1

*Instrument Case                      1

*Guarantee Card                       1

*Packing List                             1