- detailed
- Technical index
V-1 STANDARD BLOCK
For calibrating ultrasonic flaw detection equipment in both laboratory and on-site conditions. Includes a 100mm radius, 1.5mm and 50.0mm holes,engraved reference mark scales, and slots at the zero point which provide calibrating signals at intervals of 100mm range. In accordance with British Standard BS 2704 Block A2 Mod. 1, DIN 54-120, and ISO 2400.
- Dimensions: 300mm x 100mm x 25mm
-Engineering plastics storage cases
- Net Weight: 5.0kg Gross Weight: 6.5kg Approximate Weight (Carbon Steel)
V-2 STANDARD BLOCK
12.5mm thick small calibration block for on-site checking if miniature shear wave probe index,line base,beam angle and gain. Includes a 25mm and 50mm radius, 5mm hole (or 1.5mm),engraved reference mark scales from 35 to 75 degrees. In accordance with British Standard BS 2704 block A4, DIN54122.
-Dimensions: 75mm x 43mm x12.5mm
-Engineering plastics storage cases
- Net Weight: 0.5kg Gross Weight: 0.75kg Approximate Weight (Carbon Steel)
DC TEST BLOCK
AWStype block used for shear wave distance calibration. Contains a 25.4mm radius overlaying a 50.8mm radius on a 180o segment. In accordance with ASTM E164 and BRR/AWS X-1 specifications.
- Dimensions: 50.8mm and 25.4mm radii
- Engineering plastics storage cases
-Net weight: 0.5kg Gross Weight: 1.5kg Approximate Weight (Carbon Steel)
SC TEST BLOCK
AWS-type block used for shear wave sensitivity calibration. Include 1.6mm holes,in accordance with ASTM E164.
-Dimensions: 76.2mm x 31.75mm x 22.99mm
-Engineering palstics storage cases
- Net weight: 0.5kg Gross Weight: 1.0kg Approximate Weight (Carbon Steel)
DS TEST BlOCK
AWStype block used for longitudinal distance and sensitivity calibration. Contains a 50.8mm high section between two 101.6mm sections, in accordance with ASTM E164.
-Dimensions: 152.4mm x 101.6mm x 50.8mm
- Engineering palstics storage cases
-Net weight: 5.15kg Gross Weight: 6.1kg Approximate Weight (Carbon Steel)
DSC TEST BLOCK
AWStype block used for shear wave distance and sensitivity calibration. Contains a 25.4mm radius overlaying a 76.2mm radius, in accordance with ASTM E164.
-Dimensions: 25.4mm and 76.2mm radii
-Engineering palstics storage cases
-Net weight: 0.75kg Gross Weight: 1.25kg Approximate Weight (Carbon Steel)
RC TEST BLOCK
The reference block is used for checking resolution capabilities of angle beam transducers. Contains three sets of 1.6mm diameter through-holes for 45o,60o,70o. In accordance with AWS Welding Highway and Structural Welding Code ANSI/AWS D1.1
- Dimensions: 152.4mm x 76.2mm x 25.4mm
- Engineering palstics storage cases
- Net weight: 2.35kg Gross Weight: 3.3kg Approximate Weight (Carbon Steel)