thumb

JZT502 fracture sounder

Maximum test depth of concrete crack: less than 500 mm
Test error: 5% ~ 10% of the actual seam depth
Maximum correction depth of damage layer: 35mm
No cross stitch test points: 3
Data transfer interface: USB
Cross stitch test points: 2 or 3 (instrument automatic selection)
Test data storage: 25,000 test data
  • detailed
  • Technical index

Technical features:
1. Quadruple automatic correction to improve test accuracy:
Non-cross stitch measurement: automatic reminder of abnormal data in the test.
Sound velocity calculation: automatically remove the flat test intercept.
Seam depth test: automatic selection of the wrong test data.
Deep calculation: the influence of the carbonation depth and other damage layer is automatically corrected.
2. Dedicated on-site crack depth test supports ensure the accuracy of measuring point spacing and improve greatly
Detection accuracy, save detection time.
3. More scientific detection theory, improved the reliability of test results;
Main technical indicators:
The software of crack depth analysis of the middle - China extension co
1. Maximum test depth of concrete cracks: less than 500 mm
2. Test error: 5 % ~ 10% of the actual seam depth
3. Maximum correction depth of damage layer: 35mm
4. No cross stitch test points: 3
5. Cross stitch test points: 2 or 3 (instrument automatic selection)
6. Test data storage: 25,000 test data
7. Data transmission interface: USB
8. Power supply: charge battery, power supply time can reach 50 hours
9. Host volume: 220 * 162 * 91mm
Instrument composition:
Includes: host, bracket, connector, plane transducer, software CD, etc.