JUT500 Ultrasnic Flaw Detector

Measuring range:0-6000mm
Material Velocity:1000 m/s~15000m/s
Gain:0-130dB
Working Frequency:0.2-15MHz
Channels :100
D-Delay:-20µs~+3400µs
P-Delay:0µs~99.99µs
  • detailed
  • Technical index

Features:

*Automated calibrationAutomated gain

*DACAVGTCGB scanAWS

*High-speed capture and very low noise

*High contrast viewing of the waveform from bright

*Powerful pc software and reports can be export to excel


Functions:

*Automated display precise flaw location(Depth dlevel pdistance samplitudesz dBф);

*Automated switch three staff gauge ((Depth dlevel  pdistance s);

*Automated calibration of transducer Zero-point, Angles, Front edge and material Velocity;

*Convenient to make and use DACTCG and AVG to evaluate the echo, the curve can be modified and compensated

*6dB DAC functions;

*500 independence setup, any criterion can be input freely, we can work in the scene without test block;

*Big memory of 500 A graph;

*Automated gain and gain scan;

*Peak Hold and Peak Memory;

*B scan;

*AWS D1.1

*Automated make video of test process and play; use upan,the length of video is unlimited.

*Powerful pc software and reports can be export to excel;

*Li battery, continue working time up to 12 hours;

*The embeded software can be online updated


Other assistant function:

*Display freeze;

*Automated echo degree;

*Angles and K-value;  

*Lock and unlock function of system parameters;

*Electronic clock calendar ;  

*Two gates setting and alarm indication;

*Gate and DAC alarm;


Specifications:

*Measuring Range (mm):0~6000mm

*Channels: 100

*Frequency Range (MHz)0.2~15MHz

*Material Velocity (m/s): 1000~15000m/s

*Vertical Linearity Error: ≤3%

*Horizontal Linearity Error: ≤0.1%

*Sensitivity Leavings: ≥62dB

*Dynamic range: ≥32dB

*Resolving Power: ≥36dB

*Gain (dB): 0~120dB

*Measurement Mode: SingleDualThru

*Reject: 0~80%

*Pulse Displacement (μs): -20~+3400

*Zero (μs): 0.0~99.99

*Port Type: BNC(Q9)

*Operating Temperature (℃): -20~70

*H*W*D(mm): 238*160*50

*Weight (kg):1.0with battery


StandardConfigration:

*Main Body                            1

*Straight Beam Probe             1

*Angle Probe                          1

*Machine-probe Cable            2

*Power Adapter (Charger)       1

*Data proceeding Software     1

*USB communication Cable    1

*Manual                                 1

*Instrument Case                   1

*Guarantee Card                    1